12-20 July 2017
BEXCO
Asia/Seoul timezone
Home > Timetable > Session details > Contribution details

Contribution

BEXCO - Room F(201/202/203/204)

[CRI021] Simulation and experimental result of daily CR detection rate by an array including 5 detectors

Speakers

  • Masoume REZAIE

Primary authors

Co-authors

Description

An array including 5 scintillation detectors in a pentagon configuration, similar to the central cluster of Alborz-1, is constructed at the biggest building rooftop of Sharif University of Technology (the same location of Alborz-1 proposal). Data of 10 week operation is used to get the average daily Rate of CR detection. Comparing obtained experimental value of daily rate (2697) by that of simulation (3308) shows about 22.7% discrepancy. Optimization of simulation code based on experimental results is discussed.